Images are representations only.

MultiRanger/HydroRanger 100/200 Ultrasonic Level Controller

Brand: Siemens AG
Does not ship to OH, United States
MultiRanger/HydroRanger is a versatile short- to medium-range ultrasonic single- and multi-vessel level monitor/controller for virtually any application in a wide range of industries. 

MultiRanger/HydroRanger can be used on different materials, including fuel oil, municipal waste, acids, woodchips or on materials with high angles of repose.
Features
  • Differential Measurement And Six Control Relays
  • Process Intelligence
  • Range Of Models For Simple Level Measurement Or Pump Control To More Complex For Differential Level, Open Channel Measurement, Advanced Pump Control, Alarming, And Gate Control
  • Auto False-Echo Suppression To Avoid False Echoes From Fixed Obstructions
  • Intuitive Ease Of Use
show more
MultiRanger/HydroRanger is a versatile short- to medium-range ultrasonic single- and multi-vessel level monitor/controller for virtually any application in a wide range of industries. 

MultiRanger/HydroRanger can be used on different materials, including fuel oil, municipal waste, acids, woodchips or on materials with high angles of repose.
Features
  • Differential Measurement And Six Control Relays
  • Process Intelligence
  • Range Of Models For Simple Level Measurement Or Pump Control To More Complex For Differential Level, Open Channel Measurement, Advanced Pump Control, Alarming, And Gate Control
  • Auto False-Echo Suppression To Avoid False Echoes From Fixed Obstructions
  • Intuitive Ease Of Use

Specifications

Brand

Measuring Range

  • 0.3 ... 15 m (1 ... 50 ft)
  • transducer dependent

Measuring Points

  • 1 or 2

Input Analog

  • 0 ... 20 mA or 4 ... 20 mA, from alternate device, scalable

Input Discrete

  • 10 ... 50 Vdc switching level Logical 0 < 0.5 Vdc Logical 1 = 10 ... 50 Vdc Max. 3 mA

Output EchoMaximum Transducer

  • 44 kHz

Output Ultrasonic Transducer

  • Compatible transducers: ST-H and EchoMax. series XPS-10, XPS-15/15F, and XRS-5

Relays

  • Version with 1 relay (MultiRanger 100 only) 1 SPST Form A
  • Version with 3 relays 2 SPST Form A/1 SPDT Form C
  • Version with 6 relays 4 SPST Form A/2 SPDT Form C
  • Model with 1 relay 1 SPST Form A
  • Model with 3 relays 2 SPST Form A/1 SPDT Form C
  • Model with 6 relays 4 SPST Form A/2 SPDT Form C

mA Output

  • 0 ... 20 mA or 4 ... 20 mA
  • Maximum load 750 ohms, isolated
  • Resolution 0.1 % of Range

Error in Measurement

  • 0.25 % of Range or 6 mm (0.24 inch), whichever is greater
  • ± 4 mm (0.16 inch) in combination with an XRS-5 transducer on ranges 4 m (13 ft) or less

Resolution

  • 0.1 % of Measuring Range or 2 mm (0.08 inch), whichever is greater

Temperature Compensation

  • -50° to +150° C (-58° to +302° F)
  • Integral temperature sensor
  • External TS-3 temperature sensor (optional)
  • Programmable fixed temperature values

Installation Conditions

  • Location Indoor/outdoor
  • Installation category II
  • Pollution Degree 4

Ambient Conditions

  • Ambient temperature (Housing) -20° to +50° C (-4° to +122° F)
  • Storage temperature -20° to +50° C (-4° to +122° F)

Weight

  • Wall Mount 1.37 kg (3.02 lb)
  • Panel mount 1.50 kg (3.31 lb)

Material (Enclosure)

  • Polycarbonate

Degree of Protection (Enclosure)

  • Wall Mount IP65/Type 4X/NEMA 4X
  • Panel mount IP54/Type 3/NEMA 3

Transducer and mA Output Signal

  • 2-core Copper Conductor, twisted, shielded, 0.5 ... 0.75 mm²
  • (22 ... 18 AWG), Belden 8760 or equivalent is acceptable

Maximum Separation Between Transducer and Transceiver

  • 365 m (1 200 ft)

Displays and Controls

  • 100 x 40 mm (4 x 1.5 inch) multi-block LCD with backlighting

Programming

  • Programming using hand-held programmer, SIMATIC PDM or via PC with Dolphin Plus software

Power Supply

  • AC version 100 ... 230 Vac ± 15 %, 50/60 Hz, 36 VA (17 W)
  • DC version 12 ... 30 Vdc (20 W)

Certificates & Approvals

  • CE
  • RCM
  • EAC
  • KCC
  • FM
  • CSAUS/C
  • UL listed
  • Lloyd’s Register of Shipping
  • CSA Class I, Div. 2, Groups A, B, C, and D, Class II, Div. 2, Groups F and G, Class III (wall mount only), ATEX II 3D, EAC Ex

Communication

  • RS-232 with Modbus RTU or ASCII via RJ-11 connector
  • RS-485 with Modbus RTU or ASCII via terminal blocks
  • Optional: SmartLinx cards for - PROFIBUS DP - DeviceNet

Applications

  • Wet Wells
  • Flumes/Weirs
  • Bar Screen Control
  • Hoppers
  • Chemical Storage
  • Liquid Storage
  • Crusher Bins
  • Dry Solids Storage