SITRANS LT500 HydroRanger/MultiRanger Level Controller
Does not ship to OH, United States
Description
SITRANS LT500 is the next evolution of digital level, flow, and pump controllers for radar and ultrasonic transmitters – or any 2-wire 4-20 mA device. 
It is the first choice for radar sensor measurements at 80 GHz and features single and dual point measurements, 6 relays, and Modbus RTU, HART, PROFIBUS DP, PROFIBUS PA, PROFINET.
Features- Easy To Use HMI Display With Local Four-Button Programming, Menu-Driven Parameters, And Wizard Support For Key Applications
 - English, German, French, Spanish, Chinese, Italian, Portuguese, Japanese, Danish, Dutch, Swedish, Finnish, Polish, And Russian Texts On The HMI.
 - Removable Terminal Blocks For Ease Of Wiring.
 - Digital Input For Back-Up Level Override From Point Level Device.
 - Communication Options For HART, Modbus RTU, PROFIBUS PA, PROFIBUS DP and ProfiNet.
 - Single or Dual Point Level Monitoring.
 - Auto False-Echo Suppression For Fixed Obstruction Avoidance
 - Up To 6 Independent Programmable Relays For Pump Control, Alarms, Or Remote Totalization.
 - Level, Volume, And Flow Measurements In Open Channels, Differential Control, Extended Pump Control, And Alarm Functions.
 - Wall And Panel Mounting Options.
 - Remote Configuration Via EDD With SIMATIC PDM Or SITRANS DTM
 
Configure
Specifications
Specifications
Brand
Sensor Input Number of Inputs
- 1 or 2
 
Sensor Input Terminal Voltage
- Maximum 26 V, min. 18 V (0 - 22.6 mA)
 
Sensor Input Wiring
- 2 conductor, twisted, shielded, 0.5 to 0.75 mm² (22 to 18 AWG)
 
Sensor Input Maximum Cable Length
- 500 m (1 640.42 ft)
 
Sensor Input Communication
- 4-20 mA
 - HART protocol, for supported sensors: SITRANS LR110, LR120, SITRANS Probe LU240
 
Sensor Input 4 ... 20 mA Sensor Input
- Resolution 0.025 % of Full Scale
 - Accuracy 0.1 % of Full Scale
 
Sensor Input HART Sensor Input
- Resolution and accuracy are dependent on connected sensor
 
Digital Input Quantity
- 2
 
Digital Input Switching Threshold, Low
- 0° to 0.5 Vdc
 
Digital Input Switching Threshold, High
- 10-50 Vdc
 
Digital Input Current
- Maximum 3 mA
 
Digital Input Bias Voltage
- 24 V
 
Analog Output Quantity
- 2
 
Analog Output Range
- 0-20 mA or 4-20 mA
 - Maximum load 750 ohm
 - Resolution 0.1 % of Range
 
Analog Output Accuracy
- ± 20 µA
 
Analog Output Wiring
- 2 conductor, twisted, shielded, 0.5 to 0.75 mm² (22 to 18 AWG)
 
Remote Display Lid
- IP65/Type 3/NEMA 3
 
Cable Transducer and mA Output Signal
- Transducer, mA output: 2 copper conductors, twisted, with foil shield/drain wire, 300 V 0.5 … 0.75 mm² (22 … 18 AWG)
 - Relay/power to be copper conductors per local requirements to meet 250 V 5 A contact rating
 
Relay Output Quantity
- Up to 6
 - 4 form A
 - 2 form C
 
Relay Output Rating
- 5 A at 250 Vac, non-inductive
 
Installation Conditions
- Location Indoor/outdoor
 - Installation category II
 - Pollution Degree 4
 
Ambient Conditions
- Ambient temperature -20° to +50° C (-4° to +122° F)
 - Storage temperature -20° to +50° C (-4° to +122° F)
 
Weight
- Wall Mount 1.22 kg (2.68 lb)
 - Panel mount 1.35 kg (2.97 lb)
 
Enclosure
- Material Polycarbonate
 
Degree of Protection
- Wall Mount IP65/Type 4X
 - Panel mount IP54/Type 3
 
LCD Display
- 60 x 40 mm (2.36 x 1.57 inch) LCD, 240 x 160 pixels resolution
 
Menu Navigation
- 4 push button keys
 
Memory Card
- 8 GB Industrial micro SD
 
Power Supply AC Version
- 100-230 Vac, ± 15 %, 50/60 Hz, 36 VA (17 W)
 
Power Supply DC Version
- 12-30 Vdc (20 W)
 
Certificates & Approvals
- CE
 - UKCA
 - RCM
 - EAC
 - FM
 - CCSAUS
 - cULus Listed
 
Service Interface
- USB 2.0 mini A cable
 
Optional Fieldbus
- HART, with Active/Passive 4-20 mA
 - Modbus RTU
 - PROFIBUS PA
 - PROFIBUS DP
 - ProfiNet
 
Applications
Applications
- Wet Wells
 - Bar Screen Control
 - Flumes/Weirs
 - Chemical Storage
 - Liquid Storage
 - Hoppers
 - Crusher Bins
 - Dry Solids Storage