GB-M/GB-T SSI Magnetostrictive Linear Position
Does not ship to OH, United States
Description
Robust, non-contact and wear free, the Temposonics linear position sensors provide the best durability and accurate position measurement solutions in harsh industrial environments.
The position measurement accuracy is tightly controlled by the quality of the waveguide which is manufactured by MTS Sensors.
The position magnet is mounted on the moving machine part and travels non-contact over the sensor rod with the built-in waveguide. The GB-M/GB-T is an extension of the GB-Series.
Its compact housing can be easily mounted, even if there is only limited space. Due to the high temperature resistance, no measures for cooling the sensor have to be taken – saving you time and work.
Further advantages of the GB-M/GB-T sensor are: Turn me, Replace me, Program me.
Features- Sensor element and electronics can be changed
- Flat and compact sensor electronics housing
- Electrical connection is freely rotatable
Specifications
Specifications
Approvals & Certifications
- ISO 9001
- CE
- EMC Electromagnetic Emission EN 61000-6-4, Immunity EN 61000-6-2
Cable Material
- PUR
- Silicone
- Teflon
Communication
- Synchronous Serial Interface
Consumption
- Current Consumption: 90 mA Typical
Electrical Connectors
- Cable
- M12 (8-Pin) Male Connector
- M16 (7-Pin) Connector Male
Electrical Protection
- Overvoltage Protection: up to 36 Vdc
- Polarity Protection: up to -30 Vdc
Enclosure, Body Material
- Sensor Electronics: AISI 303 Stainless Steel 1.4305
Environmental Protection
- Ingress Protection: IP67 with Proper Mating Connector
- Ingress Protection: IP68 for Cable Outlet
Length
- Stroke Length: 1 to 128” (25 to 3,250 mm)
Linearity
- ≤ ± 0.02 % of Full Scale (Min. ± 60 µm) Typical
Materials of Construction
- Sensor Rod: AISI 303 Stainless Steel 1.4305
- Sensor Rod: AISI 304L Stainless Steel 1.4306, 1.4307
Metric Connection
- M18 x 1.5-6 G
Mounting Position
- Any Orientation
Operating Pressure
- psi: 10,153 (kPa: 70,000, bar: 700) Peak (At 10 x 1 Min)
- psi: 5,076 (kPa: 35,000, bar: 350)
Operating Temperature
- -40° to 90° C (-40° to 194° F)
- Option: -40° to 100° C (-40° to 212° F)
Operating Voltages
- 24 Vdc (-15 / 20 %)
Principle of Operation
- Magnetostrictive Principle
Repeatability
- ≤ ± 0.005 % of Full Scale (Min. ± 20 µm) Typical
Resolution
- Minimum 5 µm
Rotation
- 360°
Shock
- 100 G (Single Shock) IEC 60068-2-27
UNF/UNC Connection
- 3/4”-16 UNF Male-3A
Vibration
- 15 G (10 to 2,000 Hz) IEC 60068-2-6 (Resonance Frequencies Excluded)
Voltage
- Dielectric Strength: 500 Vdc (DC Ground to Machine Ground)