Level Plus SoClean Magnetostrictive Liquid Level Transmitter
Does not ship to OH, United States
Description
The Level Plus SoClean liquid level transmitter satisfies the demand for an accurate and robust liquid-level sensor with unsurpassed flexibility to meet most process application conditions.
The SoClean transmitter provides 3-in-1 measurement using one process opening for product level, interface level, and temperature measurements.
Once the transmitter is installed and calibrated there is no requirement for scheduled maintenance or recalibration.
Features- 3-in-1 measurement
- Product
- Interface
- Temperature
- No scheduled maintenance or recalibration
- Inherent accuracy ±1 mm
- Intrinsically safe
- Sanitary finish Ra 25 μin (0.64 μm)
- Electropolished finish Ra 15 μin (0.38 μm)
Specifications
Specifications
Accuracy
- Inherent Accuracy: ± 0.039” (± 1 mm)
- Temperature Accuracy (Analog, HART): ± 0.28° C (± 0.5° F) Range -40° to 105° C (-40° to 221° F)
- Temperature Accuracy (Modbus, DDA): ± 0.1° C (± 0.2° F) Range -20° to 70° C (-4° to 158° F)
- Temperature Accuracy (Modbus, DDA): ± 0.15° C (± 0.3° F) Range 70° to 100° C (158° to 212° F)
- Temperature Accuracy (Modbus, DDA): ± 0.2° C (± 0.4° F) Range -40° to -20° C (-40° to -4° F)
- Temperature Accuracy (Modbus, DDA): ± 0.5° C (± 0.9° F) Range 100° to 105° C (-40° to 221° F)
Approvals & Certifications
- ISO 9001
- ATEX Ex
- CE
- CEC
- EMC EN 61326-1, EN 61326-2-3, EN 61326-3-2, EN 61000-6-2, EN 61000-6-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11
- FM
- IEC
- NEC
BSP Connection
- 3/4” BSPP Male Fitting
Communication
- Output Signal/Protocol: HART
- Output Signal/Protocol: Modbus RTU
Electrical Connectors
- 4-Wire Shielded Cable or Twisted Pair
- NEMA Typical 4X: 1/2” NPT Female Conduit Opening
- Single & Dual Cavity: 3/4” NPT Female Conduit Opening
- Single & Dual Cavity: M20 for ATEX/IECEx Version
Electrical Protection
- Reverse Polarity Protection: Series Diode
Environmental Protection
- Hazardous Area
- Intrinsically Safe
- IP65
- IP66
- NEMA 4X
Humidity
- 0 to 100 % Relative Humidity, Non-Condensing
Length
- Sanitary Pipe: 12 to 300” (305 to 7,620 mm)
Materials of Construction
- Epoxy Coated Aluminum
- Non-Wetted Parts: 316L Stainless Steel
NPT Connection
- 3/4” NPT MaleFitting
Operating Temperature
- Electronics: -40° to 71° C (-40° to 160° F)
- Sensing Element: -40° to 125° C (-40° to 257° F)
- Temperature Element: -40° to 105° C (-40° to 221° F)
Pressure Range
- bar: 0 to 137.9
- kPa: 0 to 13,790
- psi: 0 to 2,000
- Vessel Pressure Rigid Pipe psi: 2,000 (kPa: 13,790, bar: 137.9)
Principle of Operation
- Magnetostrictive Principle
Repeatability
- 0.001 % of Full Scale
- 0.015” (0.381 mm)
Voltage
- Input Voltage: 10.5-28 Vdc
Wetted Materials
- 316L Stainless Steel