Images are representations only.

MH-Series MS Analog/Digital Magnetostrictive Linear Position Sensor

Brand: Temposonics an Amphenol Company
Does not ship to VA, United States
Temposonics sensors can be used in versatile mobile machines without any restriction and replace contact-based linear sensors like potentiometers. 

Highly dynamic systems are controlled safely by means of Temposonics sensors, thus enhancing the productivity, availability and quality of the working process of the machine. 

Insensitive to vibration, shocks, dust and weathering influence and electro-magnetic disturbances. 

Temposonics MH Series sensors are successfully used in front axle and articulated frame steering cylinders, hydraulic jacks and in steering systems for hydraulic units on agricultural and construction machinery.
show more
Temposonics sensors can be used in versatile mobile machines without any restriction and replace contact-based linear sensors like potentiometers. 

Highly dynamic systems are controlled safely by means of Temposonics sensors, thus enhancing the productivity, availability and quality of the working process of the machine. 

Insensitive to vibration, shocks, dust and weathering influence and electro-magnetic disturbances. 

Temposonics MH Series sensors are successfully used in front axle and articulated frame steering cylinders, hydraulic jacks and in steering systems for hydraulic units on agricultural and construction machinery.

Specifications

Approvals & Certifications

  • ISO 9001 (DQS), 14982 Agricultural & Forest Machines
  • EMC EN 13309 Construction Machines, Immunity: ISO 11452-2 (200 V/m Antenna), ISO 11452-4 (200 mA BCI), Emissions: CISPR 16, 25 Transiente Impulses: ISO 7637-2, E.S.D.: ISO /TR 10605

Communication

  • Baud Rate: 50 to 1,000 Kbps
  • CANopen

Consumption

  • Current Consumption (12 Vdc): Typical ≤ 100 mA
  • Current Consumption (24 Vdc): Typical ≤ 50 mA

Current

  • Analog Inrush Current: Max.
  • Analog Load Current (Output Vdc): Typical 0.5 mA - 12, 24 Vdc
  • Digital Inrush Current: Max.

Electrical Connectors

  • M12 Connector

Electrical Protection

  • Overvoltage Protection (Gnd-Vdc): up to 36 Vdc - 12 Vdc (8-32 Vdc)
  • Polarity Protection Ground-Vdc: up to -36 Vdc - 12 Vdc

Enclosure, Body Material

  • AISI 303 Stainless Steel 1.4305

Environmental Protection

  • M12 Connector: EN 60529 (IP69K) when Plugged
  • Sensor Housing: EN 60529 (IP67)

Flange Material

  • M12 Flange: Brass Nickel-Plated with O-Ring 13 x 1.6 NBR 70

Humidity

  • EN 60068-2-30, 90 % Relative Humidity, Non-Condensing

Hysteresis

  • Digital: ± 0.1 mm

Insulation Resistance

  • ≥ 10 megaohms at 60 seconds

Length

  • Analog Stroke Range: 1.9 to 98.4” (50 to 2,500 mm)
  • Digital Stroke Range: 2 to 60” (50 to 1,500 mm)

Linearity

  • 0050 to 0250 mm: ≤ ± 0.1 mm
  • 0255 to 1,500 mm: ± 0.04 % of Full Scale
  • Analog 2005 to 2,500 mm: ≤ ± 0.8 mm

Load

  • (Analog Load (Output mA), ≤ 250 ohms - 12 Vdc
  • Analog Load (Output mA): ≤ 500 ohms - 24 Vdc
  • Analog Load (Output Vdc): ≥ 10 kiloohms

Materials of Construction

  • M12 Connector Insert Pins: Brass with Gold-Plated Pins
  • M12 Connector Insert: Polyamide Reinforces
  • Pressure Pipe: AISI 304L Stainless Steel 1.4306

Mounting Position

  • Any Orientation

O-Ring Material

  • Sealing O-Ring (23.47 x 2.62 mm), M12 Connector Insert (7 x 1.35 mm): NBR

Operating Pressure

  • Nominal psi: 4,351 (kPa: 30,000, bar: 300)

Operating Temperature

  • Electronics: -40° to 105° C (-40° to 221° F)

Output

  • Analog Output: 0.25-4.75 Vdc
  • Analog Output: 0.5-4.5 Vdc
  • Analog Output: 4-20 mA

Overpressure & Static Pressure Limits

  • Maximum

Power

  • Analog Power Drain: < 1 W
  • Digital Power Drain: < 1.5 W

Process Temperature

  • -30° to 85° C (-22° to 185° F)

Proof Pressure

  • Maximum

Range

  • Digital Velocity Range: 0 to 1,000 mm/sec

Repeatability

  • Analog: ± 0.1 mm

Resolution

  • Analog Typical, Digital (Position): 0.1 mm
  • Digital (Velocity): 1 mm/sec (Velocity)

Sample Rate

  • Analog Internal Sample Rate: 2 milliseconds
  • Digital Internal Sample Rate: 1 millisecond

Shock

  • 50 G, 11 milliseconds at 1,000 Shocks Per Axis
  • IEC 60068-2-27, 100 G, 11 milliseconds Single Shock

Storage Temperature

  • -25° to 65° C (-13° to 149° F)

Supply Voltage

  • 12-24 Vdc

Tolerance

  • Analog Set Point Tolerance: ≤ 1 mm
  • Digital Set Point Tolerance: ± 0.2 mm

Vibration

  • IEC 60068-2-64, 15 G (r.m.s.), Ø 7 mm Pressure Pipe (10 to 2,000 Hz) - Resonance Frequencies Excluded

Voltage

  • Electric Strength: 500 Vdc (Ground-Vdc)

Applications

  • Harsh Environment in Mobile Hydraulic Applications