C-Series H2-Sensor Analog Position Sensor
Does not ship to VA, United States
Description
The absolute Temposonics linear position sensors are based on the MTS developed magnetostrictive measurement principle.
That combines various magneto-mechanical effects and uses the physical precise speed-measurement of an ultrasonic wave (torsion pulse in its sensor element) for position detecting.
Sensor integrated signal processing transforms the measurements directly into market standard outputs.
The contactless principle - an external movable magnet marks the position - eliminates the wear, noise and erroneous signal problems and guarantees the best durability without any recalibration.
Features- Contactless measurement – entirely wear-free
- Low weight – ideal for small portable OEM products
- Cost-efficient
- Space-saving
- No wear – no need for periodic re-adjustment
- Available with various position magnet
Specifications
Specifications
Approvals & Certifications
- ISO 9001
Approvals & Certifications
- EMC: Emission EN 61000-6-4 (CISPR 16-2-3, CIPSR 16-2-1), Immunity EN 61000-6-2 (EN 61000-4-2, 3, 4, 5, 6, 8)
Consumption
- Maximum
Electrical Protection
- Overvoltage Protection - CS: up to 19 Vdc Short Term, CM: up to 29 Vdc Short Term
- Polarity Protection Vdc - GND
Enclosure, Body Material
- 316L Stainless Steel, 1.4404
Environmental Protection
- IP67
Hysteresis
- ± 25 µm
Length
- Stroke Length: 2.8 to 9.8” (72 to 250 mm)
Linearity
- ± 0.15 mm by Means of Magnet 401842 between 5 % & 95 % of Stroke Length
Materials of Construction
- Protective Pipe: 316L Stainless Steel, 1.4404
Mounting
- Screw Mount
Operating Temperature
- -40° to 75° C (-40° to 167° F)
Output
- Analog Output: 0.1-4.9 Vdc
Output Load
- Analog: ≥ 10 kiloohms
Principle of Operation
- Magnetostrictive Principle
Repeatability
- ± 25 µm
Shock
- IEC 68-2-27 10 G, 11 milliseconds Single Hit at 1,000 Shocks Per Axis
Storage Temperature
- -20° to 85° C (-4° to 185° F)
Supply Voltage
- CM: 12 Vdc (Tolerance Range 9-15 Vdc)
- CS: 5 Vdc (Tolerance Range 4.75-5.5 Vdc)
Temperature Effect
- ± 0.005 %/°C
Tolerance
- Zero Tolerance: ± 1 mm
Update Time
- 500 Hz (2 milliseconds)
Vibration
- IEC 60068-2-6 10 G (10 to 2,000 Hz) Sinus (Resonance Frequencies Excluded)