Images are representations only.

ET Analog Magnetostrictive Linear Position Sensor

Brand: Temposonics an Amphenol Company
Does not ship to United States
Robust, non-contact and wear free, the Temposonics linear position sensors provide best durability and accurate position measurement solutions in harsh industrial environments.

The position measurement accuracy is tightly controlled by the quality of the waveguide which is manufactured by MTS Sensors.

The position magnet is mounted on the moving machine part and travels contact-lessly over the sensor rod with the built-in waveguide.
show more
Robust, non-contact and wear free, the Temposonics linear position sensors provide best durability and accurate position measurement solutions in harsh industrial environments.

The position measurement accuracy is tightly controlled by the quality of the waveguide which is manufactured by MTS Sensors.

The position magnet is mounted on the moving machine part and travels contact-lessly over the sensor rod with the built-in waveguide.

Specifications

Approvals & Certifications

  • EMC Electromagnetic Emission EN 61000-6-4, Immunity EN 61000-6-2
  • ISO 9001 (DQS)
  • QPS (C, US)

Approvals & Certifications

  • ATEX Ex
  • CE
  • CEC
  • EAC
  • IEC Ex
  • NEC

Cable Material

  • Silicone
  • Teflon

Consumption

  • Current Consumption: 100 mA Typical, Dependent on Stroke Length

Electrical Connectors

  • Cable Outlet

Electrical Protection

  • Overvoltage Protection: up to 36 Vdc
  • Polarity Protection: up to -30 Vdc

Enclosure, Body Material

  • Sensor Electronics: AISI 303 Stainless Steel 1.4305
  • Sensor Electronics: AISI 316L Stainless Steel, 1.4404

Environmental Protection

  • IP66
  • IP68

Flange Material

  • AISI 303 Stainless Steel 1.4305
  • AISI 316L Stainless Steel, 1.4404

Humidity

  • 90 % Relative Humidity, Non-Condensing

Length

  • Stroke Length: 1 to 118” (50 to 3,000 mm)

Linearity

  • ≤ ± 0.02 % of Full Scale (Min. ± 60 µm)

Load

  • 0 to 500 ohms for Current Output
  • Minimum Load Controller: > 5 kiloohms for Voltage Output

Materials of Construction

  • Sensor Rod: 304L Stainless Steel 1.4306
  • Sensor Rod: AISI 316L Stainless Steel, 1.4404

Metric Connection

  • Threaded Flange: M18 x 1.5-6 G

Mounting

  • Magnetic Mounting

Mounting Position

  • Any Orientation

Operating Pressure

  • psi: 0 to 5,076 (kPa: 0 to 35,000, bar: 0 to 350)

Operating Temperature

  • -40° to 85° C (-40° to 185° F)

Operating Voltages

  • 24 Vdc (-15 / 20 %)

Output

  • 0-10 Vdc
  • 0-20 mA
  • 10-0 Vdc
  • 20-0 mA
  • 20-4 mA
  • 4-20 mA

Principle of Operation

  • Magnetostrictive Principle

Repeatability

  • ≤ ± 0.005 % of Full Scale (Min. ± 20 µm) Typical

Resolution

  • 16-bit (Min. 1 μm Depending on Stroke Length)

Shock

  • 100 G (Single Shock), IEC 60068-2-27

UNF/UNC Connection

  • 3/4”-16 UNF Male-3A

Vibration

  • 15 G (10 to 2,000 Hz), IEC 60068-2-6 (Resonance Frequencies Excluded)

Voltage

  • Dielectric Strength: 700 Vdc (DC Ground to Machine Ground)

Applications

  • Harsh Environments
  • Metal Processing