Series FDT Flush Diaphragm Transmitter
Does not ship to VA, United States
Description
The Series FDT Flush Diaphragm Transmitter is designed for highly cyclical conditions.
Flush sensor feature prevents any potential inaccuracies due to build-up or blockage which is a typical problem found in most non-flush transmitter sensors.
Features- Performs well in high cyclical environments with the presence of water-hammering or spiking for long service life
Configure
Specifications
Specifications
Brand
Accuracy
- ± 0.5 % of Full Scale (Includes Non-Linearity, Hysteresis & Non-Repeatability)
Approvals & Certifications
- CE
Compensated Temperature
- -18° to 77° C (0° to 170° F)
Electrical Connectors
- Mating Connector for 4-Pin M-12
Environmental Protection
- IP66
- NEMA 4X
Loop Resistance
- 0 to 1.5 ohm
- 100 ohms
Media
- Compatible Gases
- Compatible Liquids
Mounting Position
- Any Orientation
NACE & NIST
- NIST Traceable Calibration Certificate
NPT Connection
- 1/4” NPT Male
Output
- 0-5 Vdc
- 4-20 mA DC
Power Requirement
- 8-38 Vdc
Pressure Range
- bar: 6.89 to 344.7
- kPa: 689.5 to 34,470
- psi: 100 to 5,000
Pressure Type
- Gauge
Response Time
- < 1 millisecond
Stability
- ± 0.25 % of Full Scale Per Year
Temperature Effect
- ± 1.5 % of Full Scale Over Compensated Range
Temperature Range
- -40° to 93° C (-40° to 200° F)
UNF/UNC Connection
- 7/16”-20 UNF Male
Wetted Materials
- 316 Stainless Steel
- 632 Stainless Steel