Images are representations only.
Description
The SITRANS TH100, which represents an economical alternative by dispensing with galvanic isolation and universal sensor connection, is ideally suited for Pt100 measurements.
For the parameterization, the SIPROM T software is used in combination with the modem for SITRANS TH100/TH200.
Its compact design makes the SITRANS TH100 suitable for retrofitting measuring points or replacing analog transmitters.
The transmitter is available in a non-Ex version and in a version suitable for use in hazardous areas.
Features- Transmitter with 2-wire system
- Mounting in connection head, type B or larger or on DIN rail
- Programmable; as a result, the sensor connection, measuring range and much more are programmable
- Intrinsically safe version for use in hazardous areas
Configure
Specifications
Specifications
Brand
Measured Variable
- Temperature
Input Type
- Pt100 according to IEC 60751
Type of Connection
- 2, 3, 4-Wire connection
Offset
- Programmable: -100° C to 100° C
Output Signal
- 4-20 mA, 2-Wire
Auxiliary Power
- 8.5 to 36 Vdc
Ambient Temperature
- -40° C to 85° C
- -40° F to 185° F
Weight
- 50 g
Degrees of Protetion
- Enclosure: IP40
- Terminals: IP00
Certifications & Approvals
- PTB 05 ATEX 2049X
- II 1 G Ex ia IIC T6/T4
- II (1) 2 G Ex ib [ia Ga] IIC T6/T4 Gb
- II (1) 3 G Ex ic [ia Ga] IIC T6/T4 Gc
- II 3 G Ex ic IIC T6/T4 Gc
- II 3 G Ex nA IIC T6/T4 Gc
- II 3 G Ex nA [ic] IIC T6/T4 Gc
- II 1 D Ex ia IIIC T115° C Da
- FM 3024169
- FM 3024169C
- EAC Ex(GOST)
- NEPSI