Images are representations only.

Series RSM Room Status Monitor

Brand: Dwyer Instruments, LLC
Does not ship to Virginia, United States
Series RSM Room Status Monitor is designed for critical low differential pressure applications that require stringent pressure monitoring and alarming.

The Series RSM can be configured to monitor positive or negative pressure in protected environments and hospital isolation rooms per CDC guidelines.

The RSM is a complete system with a graphic user interface which enables access to pressure, security, calibration, and alarm setup. The RSM has a NEMA 1 (IP20) rated fire retardant plastic for indoor applications.
Features
  • Accurately monitor protective environments for negative or positive pressure ensuring safety and reducing risk of catastrophic events
  • Audible and visual alarm provides immediate local alerts allowing corrective action to be taken quicker to eliminate the problem from becoming widespread
  • Password protected set up menu helps to insure no errors by untrained personnel
  • Optional BACnet communication from devices provides integration into building control system for automated control and centralized monitoring and alarming
show more
Series RSM Room Status Monitor is designed for critical low differential pressure applications that require stringent pressure monitoring and alarming.

The Series RSM can be configured to monitor positive or negative pressure in protected environments and hospital isolation rooms per CDC guidelines.

The RSM is a complete system with a graphic user interface which enables access to pressure, security, calibration, and alarm setup. The RSM has a NEMA 1 (IP20) rated fire retardant plastic for indoor applications.
Features
  • Accurately monitor protective environments for negative or positive pressure ensuring safety and reducing risk of catastrophic events
  • Audible and visual alarm provides immediate local alerts allowing corrective action to be taken quicker to eliminate the problem from becoming widespread
  • Password protected set up menu helps to insure no errors by untrained personnel
  • Optional BACnet communication from devices provides integration into building control system for automated control and centralized monitoring and alarming

Specifications

Accuracy

  • ± 0.5 % of Full Scale

Approvals & Certifications

  • CE
  • CSA (RSM Only)

Consumption

  • 5 W

Electrical Connectors

  • Removable Terminal Block

Enclosure, Body Material

  • Fire Retardant Plastic

Environmental Protection

  • IP20
  • NEMA 1

Humidity

  • 5 to 95 % Relative Humidity, Non-Condensing

Loop Resistance

  • 0 to 510 ohms

Media

  • Air or Non-Conductive
  • Non-Explosive Gases

Output

  • 0-10 Vdc, 3-Wire
  • 0-5 Vdc, 3-Wire
  • 4-20 mA, 2-Wire

Power Requirement

  • 5 W

Pressure Range

  • Inches WC: 0 to 2.5

Supply Voltage

  • Order Code A (24 Vac): 18 to 32 Vac, 50/60 Hz
  • Order Code B (120 Vac): 85-265 Vac, 50/60 Hz

Switch Type

  • SPST

Temperature Effect

  • ± 0.03 % of Full Scale/°F (± 0.05 % of Full Scale/°C)

Temperature Range

  • 0° to 50° C (32° to 120° F)

Tube Connection

  • 3/16” I.D. Tube

Typical Applications

  • Hospital Isolation Wards
  • Pharmaceutical
  • Manufacturing
  • Clean Rooms
  • Research Labs
  • Animal Facilities