Images are representations only.

Level Plus RefineME Magnetostrictive Liquid Level Transmitter

Brand: Temposonics an Amphenol Company
Does not ship to OH, United States
The Level Plus RefineME liquid level transmitter satisfies the demand for an accurate and robust liquid-level sensor with unsurpassed flexibility to meet most process application conditions. 

The RefineME transmitter provides 3-in-1 measurement using one process opening for product level, interface level, and temperature measurements. 

Once the transmitter is installed and calibrated there is no requirement for scheduled maintenance or recalibration.
Features
  • 3-in-1 Measurement
    • Product
    • Interface
    • Temperature
  • No Scheduled Maintenance or Recalibration
  • Inherent Accuracy ±1mm
  • Integral Display
  • Intrinsically Safe
  • API Temperature Corrected Volumes
The Level Plus RefineME liquid level transmitter satisfies the demand for an accurate and robust liquid-level sensor with unsurpassed flexibility to meet most process application conditions. 

The RefineME transmitter provides 3-in-1 measurement using one process opening for product level, interface level, and temperature measurements. 

Once the transmitter is installed and calibrated there is no requirement for scheduled maintenance or recalibration.
Features
  • 3-in-1 Measurement
    • Product
    • Interface
    • Temperature
  • No Scheduled Maintenance or Recalibration
  • Inherent Accuracy ±1mm
  • Integral Display
  • Intrinsically Safe
  • API Temperature Corrected Volumes

Specifications

Accuracy

  • Inherent Accuracy: ± 0.039” (± 1 mm)
  • Temperature Accuracy (Analog, HART): ± 0.28° C (± 0.5° F) Range -40° to 105° C (-40° to 221° F)
  • Temperature Accuracy (Modbus, DDA): ± 0.1° C (± 0.2° F) Range -20° to 70° C (-4° to 158° F)
  • Temperature Accuracy (Modbus, DDA): ± 0.15° C (± 0.3° F) Range 70° to 100° C (158° to 212° F)
  • Temperature Accuracy (Modbus, DDA): ± 0.2° C (± 0.4° F) Range -40° to -20° C (-40° to -4° F)
  • Temperature Accuracy (Modbus, DDA): ± 0.5° C (± 0.9° F) Range 100° to 105° C (-40° to 221° F)

Approvals & Certifications

  • ISO 9001
  • ATEX Ex FM14-ATEX-0068X II 1/2 G Ex ia IIC T4 Ta = -50° to 71° C
  • CE
  • CEC
  • EMC EN 61326-1, EN 61326-2-3, EN 61326-3-2, EN 61000-6-2, EN 61000-6-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11
  • FM (C,US) Class I, Div. 1, Groups A, B, C, D, T4 Class I, Zone 0/1, AEx ia IIC T4 Ta = -50 to 71° C
  • IEC Ex FMG 14.0032 II 1/2 G Ex ia IIC T4 Ga/Gb Ta = -50 to 71° C
  • NEC

BSP Connection

  • 3/4” BSPP Male Fitting

Communication

  • Output Signal/Protocol: HART
  • Output Signal/Protocol: Modbus RTU

Electrical Connectors

  • 180” (4,570 mm) Integral Cable with Pigtail
  • 4-Wire Shielded Cable
  • 4-Wire Twisted Pair Cable
  • Daniel Woodhead 6-Pin Male Connector
  • NEMA Typical 4X: 1/2” NPT Female Conduit Opening
  • Single & Dual Cavity: 3/4” NPT Female Conduit Opening
  • Single & Dual Cavity: M20 for ATEX/IECEx Version

Electrical Protection

  • Reverse Polarity Protection: Series Diode

Environmental Protection

  • Hazardous Area
  • Intrinsically Safe
  • IP65
  • IP66
  • NEMA 4X

Flange Size - 2-1/2” (DN 65)

  • 2-1/2” (DN 65) - 150#
  • 2-1/2” (DN 65) - 300#
  • 2-1/2” (DN 65) - 600#
  • 2-1/2” (DN 65) - PN 100
  • 2-1/2” (DN 65) - PN 16
  • 2-1/2” (DN 65) - PN 40
  • 2-1/2” (DN 65) - PN 64

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150#
  • 2” (DN 50) - 300#
  • 2” (DN 50) - 600#
  • 2” (DN 50) - PN 100
  • 2” (DN 50) - PN 16
  • 2” (DN 50) - PN 40
  • 2” (DN 50) - PN 64

Flange Size - 3” (DN 80)

  • 3” (DN 80) - 150#
  • 3” (DN 80) - 300#
  • 3” (DN 80) - 600#
  • 3” (DN 80) - PN 100
  • 3” (DN 80) - PN 16
  • 3” (DN 80) - PN 40
  • 3” (DN 80) - PN 64

Flange Size - 3/4” (DN 20)

  • 3/4” (DN 20) - 300#
  • 3/4” (DN 20) - 600#
  • 3/4” (DN 20) - PN 100
  • 3/4” (DN 20) - PN 16
  • 3/4” (DN 20) - PN 40
  • 3/4” (DN 20) - PN 64
  • 3/4” (DN 20) -150#

Flange Size - 4” (DN 100)

  • 4” (DN 100) - 150#
  • 4” (DN 100) - 300#
  • 4” (DN 100) - 600#
  • 4” (DN 100) - PN 100
  • 4” (DN 100) - PN 16
  • 4” (DN 100) - PN 40
  • 4” (DN 100) - PN 64

Flange Size - 5” (DN 125)

  • 5” (DN 125) - 150#
  • 5” (DN 125) - 300#
  • 5” (DN 125) - 600#
  • 5” (DN 125) - PN 100
  • 5” (DN 125) - PN 16
  • 5” (DN 125) - PN 40
  • 5” (DN 125) - PN 64

Flange Size - 6” (DN 150)

  • 6” (DN 150) - 150#
  • 6” (DN 150) - 300#
  • 6” (DN 150) - 600#
  • 6” (DN 150) - PN 100
  • 6” (DN 150) - PN 16
  • 6” (DN 150) - PN 40
  • 6” (DN 150) - PN 64

Flange Type

  • Raised Face (RF)

Humidity

  • 0 to 100 % Relative Humidity, Non-Condensing

Input

  • 10.5-28 Vdc

Length

  • Rigid Pipe: 12 to 300” (304.8 to 7,620 mm)

Materials of Construction

  • 316L Stainless Steel
  • Epoxy Coated Aluminum

Mounting

  • Flange Mount

NPT Connection

  • 3/4” NPT MaleFitting

Operating Temperature

  • Electronics: -40° to 71° C (-40° to 160° F)
  • Sensing Element: -40° to 125° C (-40° to 257° F)
  • Temperature Element: -40° to 105° C (-40° to 221° F)

Output

  • Analog Output: 4-20 mA

Pressure Range

  • bar: 1.724 to 137.9
  • kPa: 172.4 to 13,789
  • psi: 25 to 2,000
  • Vessel Pressure (Rigid Pipe) - psi: 2,000 (kPa: 13,790, bar: 137.9)
  • Vessel Pressure (Teflon Pipe) - psi: 25 (kPa: 172.4, bar: 1.75)

Principle of Operation

  • Magnetostrictive Principle

Repeatability

  • 0.001 % of Full Scale
  • 0.015” (0.381 mm) (Any Direction)

Wetted Materials

  • 316L Stainless Steel
  • Hastelloy C
  • Teflon

Applications

  • Inventory Control
  • Bulk Storage
  • Alkylation
  • Petroleum and Petrochemical
  • LPG Terminals
  • Mining