Series 442 Programmable HART® Temperature Transmitter
Does not ship to OH, United States
Description
The Series 442 programmable HART® temperature transmitter is a 2-wire transmitter with an analog output.
It has measurement input for resistance thermometers (RTD) in 2-, 3- or 4-wire connections, thermocouples, resistance and voltage inputs. The transmitter can be programmed with a PC or HART® protocol hand-held terminal.
These small units can be mounted in Pyromation DIN (Form B) connection heads, or they can be used for surface mounting by using a 35 mm DIN-rail mounting clip.
Features
- Universal settings with HART® protocol for various signals.
- Galvanic isolation
- 2-wire technology, (4 to 20) mA analog output
- High accuracy in total ambient temperature range
- Fault signal on sensor break or short circuit
- RFI/EMI Protected, CE marked
- cURus, UL Recognized Component
- FM Intrinsically safe and non-incendive for hazardous locations
- Output simulation
Configure
Specifications
Specifications
Brand
Connection Type
- 2-Wire
- 3-Wire
- 4-Wire
Current Limit
- ≤ 23 mA
Output Signal
- 4-20 mA or 20-4 mA
Transmission as
- Temperature Linear
- Resistance Linear
- Voltage Linear
Switch on Delay
- 4 s
Certifications & Approvals
- FM
- CSA
- cURus
- CE
- EMC
RFI/EMI
- Yes
Measurement Range
- RTD: -200° to 850° C (-328° to 1,562° F)
- Thermocouples (TC): -270° to 2,495° C (-454° to 4,523° F)
- Resistance: 10 to 2,000 Ω
- Millivolt (mV): -10 to 75 mV
Measurement Accuracy
- Type K, J, T, E, L, U: ± 0.5° C or 0.08%
- Type N, C, D: ± 1.0° C or 0.08%
- Type B: ± 2.0° C or 0.08%
- Type S, R: ± 1.4° C or 0.08%
- Millivolt (mV): ± 20 µV or 0.08%
General Accuracy
- Influence of Power Supply: ± 0.01%/V Deviation from 24 V
- Load Influence: ± 0.02%/100 Ω
- Long Term Stability: ≤ 0.1° C/year or ≤ 0.05%/year
Ambient Temperature
- -40° to 85° C (-40° to 185° F)
Storage Temperature
- -40° to 100° C (-40° to 212° F)
Vibration Protection
- 4 g / (2 to 150) Hz according to IEC 60 068-2-6
EMC Immunity
- Interference immunity and interference emission as per EN 61 326-1 (IEC 1326)