Images are representations only.

SC22 Series Safety Controller

Brand: Banner Engineering
Does not ship to VA, United States
Non-safety monitoring of the Safety Controller I/O via Ethernet network communications, including Modbus/TCP, Ethernet I/P and PCCC.
Features
  • Uses an RJ45 Ethernet connector and standard or crossover-style cordsets to communicate via Ethernet communications protocols.
  • 32 configurable virtual status outputs with "Auto Configuration" option.
  • Network access to the Fault Log and System/Network parameters.
  • 22 input terminals can monitor both contact-based or PNP solid-state outputs from Banner devices or any other manufacturers.
  • Each input can be a non-safety input, or configured for Control Reliability or Category 2, 3 or 4 safety circuit performance per ISO 13849-1.
  • 3 pairs of solid-state safety outputs rated at 0.5A each (24 V dc) with selectable one- or two-channel external device monitoring and ON-delay or OFF-delay.
  • 10 configurable auxiliary status outputs track inputs, outputs, lockout, I/O status and other functions.
  • Live Display and a Fault Log provide real-time system and fault history identification.
  • Controller is designed to meet stringent standards including Safety Integrity Level (SIL) 3 per IEC 62061 and IEC 61508, and Category 4 Performance Level (PL e) per ISO 13849-1.
Non-safety monitoring of the Safety Controller I/O via Ethernet network communications, including Modbus/TCP, Ethernet I/P and PCCC.
Features
  • Uses an RJ45 Ethernet connector and standard or crossover-style cordsets to communicate via Ethernet communications protocols.
  • 32 configurable virtual status outputs with "Auto Configuration" option.
  • Network access to the Fault Log and System/Network parameters.
  • 22 input terminals can monitor both contact-based or PNP solid-state outputs from Banner devices or any other manufacturers.
  • Each input can be a non-safety input, or configured for Control Reliability or Category 2, 3 or 4 safety circuit performance per ISO 13849-1.
  • 3 pairs of solid-state safety outputs rated at 0.5A each (24 V dc) with selectable one- or two-channel external device monitoring and ON-delay or OFF-delay.
  • 10 configurable auxiliary status outputs track inputs, outputs, lockout, I/O status and other functions.
  • Live Display and a Fault Log provide real-time system and fault history identification.
  • Controller is designed to meet stringent standards including Safety Integrity Level (SIL) 3 per IEC 62061 and IEC 61508, and Category 4 Performance Level (PL e) per ISO 13849-1.