Description
The PMS Particulate Sensor employs a field-proven combination of passive-induction and protected-probe technologies.
As particles flow near and around the probe, minute currents are dynamically induced into the probe by flowing particulate. A DSP processes the signal into an absolute output that is reasonably linear to mass.
Protective layers over the probe work in combination with induction-sensing to ensure reliable operation with all types of particulate including moist powders and highly conductive dusts. Maintenance is minimal and there is no need for an air purge.
For durability, the sensors are passive and free of electronics. The PMS Particulate Sensor is designed to be used with the DPM Particle Monitor in order to be intrinsically safe.
Features- Durable Housing That is Free of Electronics
- Minimal Maintenance Needed
Configure
Specifications
Specifications
Ambient Temperature Range
- -40° to 200° C (-40° to 392° F)
Approvals & Certifications
- CE
- CSA
Electrical Connectors
- 10-40 Foot Sensor Cable
- Low Noise Coaxial
Enclosure, Body Material
- Cast Aluminum - Painted Standared
Environmental Protection
- Intrinsically Safe
- IP66
- NEMA 4X
- Weatherproof - Class I, II, & III & Div. 1 & 2
Flange Size - 2” (DN 50)
- 150# - ANSI Flange
- 150# - ANSI Flange with Process Mating Flange
Insertion 'U' Length
- 1.5" - 72"
Media
- Air
- Compatible Gases
Mounting
- Flange Mount
NPT Connection
- 1" NPT Male with 1.5" Quick Clamp Connection
- 1/2" NPT Male
Pressure Range
- psi: 10 to 100 (kPa: 68.95 to 689.5, bar: 0.68 to 6.895)
Process Temperature
- 649° C (1200° F) - Max.
Wetted Materials
- 316 Stainless Steel - T1, T2, T3, T4
- Ceramic - T3, T4
- PFA - T1, T2