TH Analog SIL 2 Capable Magnetostrictive Linear Position Sensor
                Does not ship to OH, United States
            
    
    
    Description
The TH sensor is extremely robust and ideal for continuous operation under harsh industrial conditions. 
T-Series sensors are ATEX, IECEx, CEC and NEC certified for use in Class I, II, III Division 1, Division 2 and Zone 0/1, Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas and meet the requirements for SIL 2. 
The T-Series is offered in a ϕ 10 mm (ϕ 0.39") rod in lengths from 25 to 1,500 mm (1 to 60"). The sensor rod is capable of withstanding high pressures such as those found in hydraulic cylinders. 
Furthermore the sensor is also suitable for petrochemical plants and caustic environments. The sensor head contains the active signal conditioning and a complete integrated electronics interface.
                                            Specifications
Specifications
Approvals & Certifications
- ISO 9001 (DQS)
 - ATEX Ex db Eb IIC T4 Ga/Gb, Ex Tb IIIC T130° C Ga/Db Zone 0/1, Zone 21 -40° C ≤ Ta ≤ 85° C (Version E), Ex db IIC T4 Ga/Gb Ex Tb IIIC T130° C Ga/Db Zone 0/1, Zone 21 -40° C ≤ Ta ≤ 85° C (Version D, G)
 - CEC - Version E (Non-Incendive, Non-Sparking), Version G (Explosion-proof, Flameproof)
 - EMC Electromagnetic Emission IEC, EN 61326-1 (Class B), Immunity IEC, EN 61326-2-3 (Class B)
 - IEC Ex db Eb IIC T4 Ga/Gb, Ex Tb IIIC T130° C Ga/Db Zone 0/1, Zone 21 -40° C ≤ Ta ≤ 85° C (Version E), Ex db IIC T4 Ga/Gb Ex Tb IIIC T130° C Ga/Db Zone 0/1, Zone 21 -40° C ≤ Ta ≤ 85° C (Version D, G)
 - NEC - Version E (Non-Incendive, Non-Sparking), Version G (Explosion-proof, Flameproof)
 
Consumption
- Current Consumption: 100 mA Typical
 
Electrical Connectors
- T-Series Terminal Connection
 
Electrical Protection
- Overvoltage Protection: up to 36 Vdc
 - Polarity Protection: up to -30 Vdc
 
Enclosure, Body Material
- Sensor Electronics: AISI 303 Stainless Steel 1.4305
 - Sensor Electronics: AISI 316L Stainless Steel, 1.4404
 
Environmental Protection
- Ingress Protection Version N: IP68
 - Ingress Protection Version N: IP69K
 - Ingress Protection Version N: NEMA 4X Depending on Cable Gland
 - IP66
 - IP67
 
Flange Type
- Threaded Flange with Flat-Face (M18 x 1.5-6 G) (3/4"-16 UNF-3A)
 - Threaded Flange with Raised-Face (M18 x 1.5-6 G) (3/4"-16 UNF-3A)
 
Humidity
- 90 % RH, Non-Condensing
 
Hysteresis
- < 4 µm
 
Length
- Stroke Length: 1 to 60" (25 to 1,500 mm)
 
Linearity
- < ± 0.01 % of Full Scale (Min. ± 50 µm)
 
Load
- 0 to 500 ohms
 
Materials of Construction
- Sensor Rod: AISI 304L Stainless Steel 1.4306
 - Sensor Rod: AISI 316L Stainless Steel, 1.4404
 
Metric Connection
- M16 x 1.5-6H Female - Version E, N
 - M18 x 1.5-6 G Female
 - M20 x 1.5-6H Female
 
Mounting Position
- Any Orientation
 
NPT Connection
- 1/2"-14 Female NPT
 
Operating Pressure
- psi: 5,076 (kPa: 35,000, bar: 350) Static
 
Operating Temperature
- -40° to 85° C (-40° to 185° F)
 
Operating Voltages
- 24 Vdc (-15 / 20 %)
 
Output
- 0-20 mA
 - 20-0 mA
 - 20-4 mA
 - 4-20 mA
 
Repeatability
- < ± 0.001 % of Full Scale (Min. ± 2.5 µm)
 
Resolution
- 0.0015 % (Min. 1 µm)
 - 16-bit
 
Shock
- 100 G (Single Shock) IEC 60068-2-27
 
Temperature Coefficient
- < 30 ppm / K Typical
 
UNF/UNC Connection
- 3/4"-16 UNF Female-3A
 
Vibration
- 15 G (10 to 2000 Hz), IEC 60068-2-6 (Resonance Frequencies Excluded)
 
Voltage
- Dielectric Strength: 700 Vdc (DC Ground to Machine Ground)