Images are representations only.

C-Series M1-Sensor Analog Position Sensor

Brand: Temposonics an Amphenol Company
Does not ship to Massachusetts, United States
For position measurement, the absolute, linear Temposonics position sensors make use of the properties offered by the specially designed magnetostrictive waveguide.

Inside the sensor a torsional strain pulse is induced in the waveguide by momentary interaction of two magnetic fields.

One field is produced by a moving position magnet, which travels along the outside of the sensor rod, and the other field is generated by a current pulse applied to the waveguide.

The interaction between these two magnetic fields produces a strain pulse, which is detected at the head of the sensor.

The position of the moving magnet is determined precisely by measuring the time elapsed between the application of the current pulse and the arrival of the strain pulse.

The result is a reliable position measurement system capable of ensuring accurate and repeatable measurement.
Features
  • Contactless measurement – entirely wear-free
  • Low weight – ideal for small portable OEM products
  • Cost-efficient
  • Space-saving
  • Low energy requirement – can be operated from 5 Vdc or 12 Vdc supply
  • No need for periodic re-adjustment
  • Available with various position magnets
show more
For position measurement, the absolute, linear Temposonics position sensors make use of the properties offered by the specially designed magnetostrictive waveguide.

Inside the sensor a torsional strain pulse is induced in the waveguide by momentary interaction of two magnetic fields.

One field is produced by a moving position magnet, which travels along the outside of the sensor rod, and the other field is generated by a current pulse applied to the waveguide.

The interaction between these two magnetic fields produces a strain pulse, which is detected at the head of the sensor.

The position of the moving magnet is determined precisely by measuring the time elapsed between the application of the current pulse and the arrival of the strain pulse.

The result is a reliable position measurement system capable of ensuring accurate and repeatable measurement.
Features
  • Contactless measurement – entirely wear-free
  • Low weight – ideal for small portable OEM products
  • Cost-efficient
  • Space-saving
  • Low energy requirement – can be operated from 5 Vdc or 12 Vdc supply
  • No need for periodic re-adjustment
  • Available with various position magnets

Specifications

Approvals & Certifications

  • ISO 9001

Approvals & Certifications

  • Emission EN 61000-6-4 (CISPR 16-2-3, CIPSR 16-2-1), Immunity EN 61000-6-2 (EN 61000-4-2, 3, 4, 5, 6, 8)

Consumption

  • Power Consumption: 40 mA - Max.

Electrical Protection

  • Overvoltage Protection CS: up to 19 Vdc, CM: up to 29 Vdc Short Term
  • Polarity Protection: Vdc - GND

Enclosure, Body Material

  • AISI 303 Stainless Steel 1.4305

Environmental Protection

  • IP69K (Plugged)

Hysteresis

  • ± 25 µm

Length

  • Stroke Length: 2.8 to 9.8” (72 to 250 mm)

Linearity

  • ± 0.15 mm by Means of Magnet 401842 between 5 % & 95 % of Stroke Length

Materials of Construction

  • Protective Tube: AISI 304L Stainless Steel 1.4306

Operating Pressure

  • Maximum
  • Ø 8 mm Rod psi: 3,626 (kPa: 25,000, bar: 250)

Operating Temperature

  • -40° to 75° C (-40° to 167° F)

Output

  • Analog Output: 0.1-4.9 Vdc

Output Load

  • Analog: ≥ 10 kiloohms

Repeatability

  • ± 25 µm

Shock

  • 100 G, 11 milliseconds Single Hit (IEC 68-2-27)
  • 50 G, 11 milliseconds 1,000 Shocks Per Axis (IEC 68-2-27)

Storage Temperature

  • -40° to 85° C (-40° to 185° F)

Supply Voltage

  • CM: 12 Vdc (Tolerance Range 9-15 Vdc)
  • CS: 5 Vdc (Tolerance Range 4.75-5.5 Vdc)

Temperature Coefficient

  • ± 0.005 %/°C

Tolerance

  • Zero Tolerance: ± 1 mm

Update Time

  • 500 Hz (2 milliseconds)

Vibration

  • IEC 68-2-6 15 G (10 to 2,000 Hz) Sinus (Resonance Frequencies Excluded)

Voltage

  • Ausgang: 0.1-4.9 Vdc

Applications

  • Immunodiagnostics