Images are representations only.

Series SA1100 Diaphragm Operated Pressure Switch

Brand: Dwyer Instruments, LLC
Does not ship to OH, United States
The Series SA1100 Diaphragm Operated Pressure Switches are weatherproof and explosion-proof in one economical enclosure.

Extremely rugged construction assures excellent reliability in chemical, petroleum and industrial plants. New design also provides burst pressure protection to 3000 psi (206 bar). 

The rolling diaphragm design maintains a constant effective area to minimize friction. This results in a minimum deadband as low as 5% of full-scale. Since many applications require higher deadbands, the SA1100 includes a separate adjustment of this when necessary. 

A pump being used to control liquid level in a tank would be a typical situation where this feature would be important. Both setpoint and deadband adjustments are protected, yet clearly visible behind a clear polycarbonate window and are fully isolated from the electrical components for additional safety. A 7/16" open-end wrench is the only tool required to change settings.

Terminal blocks are provided for switch wiring connections and both internal and external ground screws are included. 

Standard housing is weatherproof to NEMA standards 1 through 4X and 13; explosion-proof to NEMA 7, Class I, Groups B, C & D; NEMA 9, Class II, Groups E, F & G. Optional construction adds drain to meet NEMA 3R IP54.
Features
  • Explosion-proof and weatherproof housing provides device protection for outdoor use or harsh environment operation
  • Burst pressure protection prevents device failure where high-pressure surges may damage device costing down-time and repair/replacement
  • Adjustable deadband reduces equipment cycling and potential failure
  • Visible set-point and deadband adjustments provide an easy and fast check without having to open device causing dangerous conditions to operators
The Series SA1100 Diaphragm Operated Pressure Switches are weatherproof and explosion-proof in one economical enclosure.

Extremely rugged construction assures excellent reliability in chemical, petroleum and industrial plants. New design also provides burst pressure protection to 3000 psi (206 bar). 

The rolling diaphragm design maintains a constant effective area to minimize friction. This results in a minimum deadband as low as 5% of full-scale. Since many applications require higher deadbands, the SA1100 includes a separate adjustment of this when necessary. 

A pump being used to control liquid level in a tank would be a typical situation where this feature would be important. Both setpoint and deadband adjustments are protected, yet clearly visible behind a clear polycarbonate window and are fully isolated from the electrical components for additional safety. A 7/16" open-end wrench is the only tool required to change settings.

Terminal blocks are provided for switch wiring connections and both internal and external ground screws are included. 

Standard housing is weatherproof to NEMA standards 1 through 4X and 13; explosion-proof to NEMA 7, Class I, Groups B, C & D; NEMA 9, Class II, Groups E, F & G. Optional construction adds drain to meet NEMA 3R IP54.
Features
  • Explosion-proof and weatherproof housing provides device protection for outdoor use or harsh environment operation
  • Burst pressure protection prevents device failure where high-pressure surges may damage device costing down-time and repair/replacement
  • Adjustable deadband reduces equipment cycling and potential failure
  • Visible set-point and deadband adjustments provide an easy and fast check without having to open device causing dangerous conditions to operators

Specifications

Adjustment Type

  • Internal 7/16” Hex Nuts

Ambient Temperature Range

  • -20° to 75° C (-4° to 167° F)

Approvals & Certifications

  • ATEX
  • CE
  • CSA
  • Ex
  • UL

Conduit Connection

  • 3/4” NPT Female

Deadband, Approximate

  • psig: 4.0 to 300 (kPa: 28 to 2,068, bar: 0.27 to 21)

Diaphragm Material

  • Buna-N
  • Fluorocarbon

Electrical Connectors

  • Screw Terminal

Electrical Rating

  • 1 A at 125 Vac
  • 1 A at 30 Vdc
  • 1/2 A at 125 Vdc
  • 1/4 A at 250 Vdc
  • 1/4 hp at 250 Vac
  • 1/8 hp at 125 Vac
  • 15 A at 125/250/480 Vac
  • 5 A at 125/250 Vac
  • 5 A at 30 Vdc

Enclosure, Body Material

  • 316 Stainless Steel
  • Aluminum

Environmental Protection

  • NEMA 1
  • Explosion-proof
  • IP66
  • NEMA 4X
  • NEMA 7
  • NEMA 9
  • Weatherproof

NPT Connection

  • 1/2” NPT Female

O-Ring Material

  • Buna-N
  • Fluorocarbon

Process Temperature

  • -20° to 75° C (-4° to 167° F)

Sensor Orientation

  • Within 20° of Vertical

Set Point - Decreasing

  • bar: 0.7 to 34
  • kPa: 68.95 to 3,447
  • psig: 10 to 500

Set Point - Increasing

  • bar: 0.7 to 34
  • kPa: 68.95 to 3,447
  • psig: 10 to 500

Switch Type

  • DPDT Snap Switch
  • SPDT

System Pressure

  • bar: 82.7
  • kPa: 8,273
  • psig: 1,200

Temperature Range

  • -35° to 82° C (-31° to 180° F)

Applications

  • Chemical, Petroleum, Food and Drug Processing Industries
  • Used Indoor, Outdoor or in Explosion-proof Area
  • Pump Control