Series TFP-GV Gas Turbine Flow Meter
Does not ship to VA, United States
Description
The Series TFP-GV Gas Flowmeters utilize a turbine wheel and electro-optical detection to convert flow rates into a linear 0 to 5 Vdc output signal for recording and data logging.
Couple this unit with a Series FIV Flow Totalizer for a remote flow monitoring display. A power adapter or mating cable assembly is required for operation.
Features- Corrosion Resistant PPS Body
- High Repeatability with Patented Microturbine Design
- Design Accurately Measures Flow Rates with No Zero Drift and No Required Maintenance
Configure
Specifications
Specifications
Accuracy
- ± 3 % of Full Scale
Air Consumption
- 0.042 to 420 scfh (0.02 to 200 LPM)
Approvals & Certifications
- CE
Consumption
- 35 mA at 12 Vdc
Elastomers
- Fluoroelastomer
Electrical Connectors
- 4-Pin Power & Signal Connector
Environmental Protection
- IP10
- NEMA 1
Linearization
- ± 3 % of Full Scale
Media
- Gas
Output
- 0-5 Vdc
Power
- 115 Vac Power Adapter
- 230 Vac Power Adapter
Power Requirement
- 11.5-15 Vdc
Pressure Range
- bar: 0 to 2.8
- kPa: 0 to 280
- psig: 0 to 40
Repeatability
- ± 0.5 % of Full Scale
Sensitivity
- ± 0.2 % of Full Scale Per °C
Storage Temperature
- 0° to 70° C (32° to 158° F)
Temperature Range
- 5° to 55° C (41° to 131° F)
Tube Connection
- 1/2” Compression Fitting
- 1/4” Compression Fitting
- 1/8” Compression Fitting
- 3/8” Compression Fitting
Wetted Materials
- Acetal
- Epoxy
- Fluoroelastomer
- Glass
- PPS
- Sapphire