SITRANS TR200 Rail Temperature Transmitter
Does not ship to Virginia, United States
Description
SITRANS TR200 is designed to support all common RTDs, thermocouples, resistance and millivolt sensors.
Setup is quick and easy with the transmitter modem and SIPROM T software.
Unique user-friendly details are implemented: one of them being the direct readout of the output current with a multimeter without having to open the 4 … 20 mA loop.
A red/green LED indicates the device status at a glance.
Transmitters of the "intrinsically safe" type of protection can be installed within potentially explosive atmospheres.
The devices meet the directive 2014/34/EU (ATEX).
Features• Compact design
• Galvanic isolation
• Test sockets for multimeters
• Diagnostics LED (green/red)
• Sensor monitoring open circuits and short-circuits
• Self-monitoring
• Configuration status stored in EEPROM
• Expanded diagnostic functions, such as slave pointer, operating hours counter, etc.
• Special characteristic
• Electromagnetic compatibility to EN 61326 and NE21
• SIL2 (with order note C20), SIL2/3 (with C23)
Configure
Specifications
Specifications
Brand
Input Sensor Type - RTD
- Pt25 … Pt1000
- Ni25 … Ni1000
Input Sensor Type - Thermocouple
- Type B, C, D, E, J, K, L, N, R, S T, U
Units of Measure
- °C
- °F
Input Connection
- 2-Wire Connection
- 3-Wire connection
- 4-Wire connection
Sensor Current
- < 0.45 mA
Output Signal
- 4-20 mA, 2-Wire
Auxiliary Power
- 11 to 35 Vdc
Ambient Temperature Range
- -40° C to 85° C
- -40° F to 185° F
Relative Humidity
- < 98 %, with condensation
Material
- Plastic, electronic module potted
Weight
- 122 g
Degree of Protection
- Enclosure: IP20
Certificates & Approvals
- PTB 07 ATEX 2032X
- II 2(1) G Ex ia/ib IIC T6/T4
- II 3(1) G Ex ia/ic IIC T6/T4
- II 3 G Ex ic IIC T6/T4
- II 2(1) D Ex iaD/ibD 20/21 T115° C
- II 3 G Ex nA IIC T6/T4
- NEPSI
- EAC Ex