Images are representations only.

TH Analog Magnetostrictive Linear Position Sensor

Brand: Temposonics an Amphenol Company
Does not ship to VA, United States
The TH sensor is extremely robust and ideal for continuous operation under harsh industrial conditions. 

T-Series sensors are ATEX, IECEx, CEC and NEC certified for use in Class I, II, III Division 1, Division 2 and Zone 0/1, Zone 1, Zone 2, Zone 21 and Zone 22 of hazardous areas. 

The T-Series is offered in a standard ϕ10 mm (ϕ 0.39") rod in lengths from 25 to 7,620 mm (1 to 300"). The sensor rod is capable of withstanding high pressures such as those found in hydraulic cylinders. 

Furthermore the sensor is also suitable for petrochemical plants and caustic environments. The sensor head contains the active signal conditioning and a complete integrated electronics interface.
show more
The TH sensor is extremely robust and ideal for continuous operation under harsh industrial conditions. 

T-Series sensors are ATEX, IECEx, CEC and NEC certified for use in Class I, II, III Division 1, Division 2 and Zone 0/1, Zone 1, Zone 2, Zone 21 and Zone 22 of hazardous areas. 

The T-Series is offered in a standard ϕ10 mm (ϕ 0.39") rod in lengths from 25 to 7,620 mm (1 to 300"). The sensor rod is capable of withstanding high pressures such as those found in hydraulic cylinders. 

Furthermore the sensor is also suitable for petrochemical plants and caustic environments. The sensor head contains the active signal conditioning and a complete integrated electronics interface.

Specifications

Approvals & Certifications

  • ISO 9001 (DQS)
  • ATEX Ex db Eb IIC T4 Ga/Gb, Ex Tb IIIC T130° C Ga/Db, Zone 0/1, Zone 21 -40° C ≤ Ta ≤ 75° C - Version D, E, G
  • CEC (Explosion-proof: Class I, Div. 1, Groups B, C, D T4, Class II/III, Div. 1, Groups E, F, G T130° C, -40° C ≤ Ta ≤ 75° C), (Flameproof: Class I Zone 0/1 Ex d IIC T4 Ga/Gb, Class II/III Zone 21 Ex Tb IIIC T130° C Db, -40° C ≤ Ta ≤ 75° C)
  • EMC Emission (IEC/EN 55011 + A1 Class B), Immunity (IEC/EN 61000-6-2)
  • IEC Ex db Eb IIC T4 Ga/Gb, Ex Tb IIIC T130° C Ga/Db, Zone 0/1, Zone 21, -40° C ≤ Ta ≤ 75° C - Version D, E, G
  • NEC (Explosion-proof: Class I, Div. 1, Grade A, B, C, D T4, Class II/III, Div. 1, Groups E, F, G T130° C, -40° C ≤ Ta ≤ 75° C), (Flameproof: Class I Zone 0/1 AEx d IIC T4, Class II/III Zone 21 AEx Tb IIIC T130° C, -40° C ≤ Ta ≤ 75° C)

Consumption

  • Current Consumption: 100 mA Typical

Electrical Connectors

  • T-Series Terminal Connection

Electrical Protection

  • Overvoltage Protection: up to 36 Vdc
  • Polarity Protection: up to -30 Vdc

Enclosure, Body Material

  • Sensor Electronics: AISI 303 Stainless Steel 1.4305
  • Sensor Electronics: AISI 316L Stainless Steel, 1.4404

Environmental Protection

  • Ingress Protection Version N: IP68
  • Ingress Protection Version N: IP69K
  • Ingress Protection Version N: NEMA 4X Depending on Cable Gland
  • IP66
  • IP67

Flange Type

  • Threaded Flange with Flat-Face (M18 x 1.5-6 G) (3/4”-16 UNF-3A)
  • Threaded Flange with Raised-Face (M18 x 1.5-6 G) (3/4”-16 UNF-3A)

Humidity

  • 90 % Relative Humidity, Non-Condensing

Hysteresis

  • < 4 µm

Length

  • Stroke Length: 1 to 300” (25 to 7,620 mm)

Linearity

  • < ± 0.01 % of Full Scale (Min. ± 50 µm)

Load

  • 0 to 500 ohms

Materials of Construction

  • Sensor Rod: AISI 304L Stainless Steel 1.4306
  • Sensor Rod: AISI 316L Stainless Steel, 1.4404

Metric Connection

  • M16 x 1.5-6H Female - Version E, N
  • M18 x 1.5-6 G Female
  • M20 x 1.5-6H Female

Mounting Position

  • Any Orientation

NPT Connection

  • 1/2”-14 Female NPT

Operating Pressure

  • psi: 5,076 (kPa: 35,000, bar: 350) Static

Operating Temperature

  • -40° to 75° C (-40° to 167° F)

Operating Voltages

  • 24 Vdc (-15 / 20 %)

Output

  • 0-20 mA
  • 20-0 mA
  • 20-4 mA
  • 4-20 mA

Repeatability

  • < ± 0.001 % of Full Scale (Min. ± 2.5 µm)

Resolution

  • 0.0015 % (Min. 1 µm)
  • 16-bit

Shock

  • 100 G (Single Shock) IEC 60068-2-27

Temperature Coefficient

  • < 30 ppm / K Typical

UNF/UNC Connection

  • 3/4”-16 UNF Female-3A

Vibration

  • 15 G (10 to 2,000 Hz), IEC 60068-2-6 (Resonance Frequencies Excluded)

Voltage

  • Dielectric Strength: 700 Vdc (DC Ground to Machine Ground)