Images are representations only.

Series HADP High Accuracy Differential Pressure Transmitter

Brand: Dwyer Instruments, LLC
Does not ship to United States
Series HADP Differential Pressure Transmitter combines low ranges with exceptional stability, reliability and an outstanding accuracy of ±0.14% Full Scale.

All models come with NIST certificates and are available in unidirectional and bi-directional ranges as low as 0 to 0.5 Inches WC and 0 to 5 psid.

The Series HADP transmitters are extremely stable allowing for use in the most demanding applications.
Features
  • High stability at low pressure ranges provides exceptional accuracy for insuring tight control and minimizing costly out of specification conditions
  • Fast warm-up and response means no lag in monitoring and control that can cause time consuming false alarm conditions
show more
Series HADP Differential Pressure Transmitter combines low ranges with exceptional stability, reliability and an outstanding accuracy of ±0.14% Full Scale.

All models come with NIST certificates and are available in unidirectional and bi-directional ranges as low as 0 to 0.5 Inches WC and 0 to 5 psid.

The Series HADP transmitters are extremely stable allowing for use in the most demanding applications.
Features
  • High stability at low pressure ranges provides exceptional accuracy for insuring tight control and minimizing costly out of specification conditions
  • Fast warm-up and response means no lag in monitoring and control that can cause time consuming false alarm conditions

Specifications

Accuracy

  • < ± 0.14 % of Full Scale

Applications

  • Clean Rooms
  • Energy/Water Management
  • Environmental Testing
  • Leak Detection
  • Medical Instruments

Approvals & Certifications

  • CE

Compensated Temperature

  • -1° to 65° C (30° to 150° F)

Consumption

  • < 30 mA

Electrical Connectors

  • 2 Foot Cable Standard

Loop Resistance

  • Maximum
  • Minimum (Vdc) = 17 + 0.02 x Resistance of Receiver Plus Line

Media

  • Compatible Non-Conducting Air
  • Compatible Non-Conducting Gas

NACE & NIST

  • NIST

NPT Connection

  • 1/8”-27 Female NPT Internal

Operating Temperature

  • -18° to 71° C (0° to 160° F)

Output

  • 0-5 Vdc for Voltage Models
  • 4-20 mA for Current Models

Power Requirement

  • 17-42 Vdc for Current Models
  • 22-30 Vdc for Voltage Models

Pressure Range

  • bar: 0 to 0.34
  • Inches WC: 0 to 15
  • kPa: 0 to 34.47
  • psid: 0 to 5

Pressure Type

  • Differential

Response Time

  • < 5 milliseconds

Sensor Orientation

  • Pressure Port 90° Parallel to Ground

Span & Zero Effect

  • Zero & Span Output: Factory Set to within ± 0.07 mA

Stability

  • < ± 0.1 % of Full Scale for 6 Months at 21° C (70° F)

Storage Temperature

  • -53° to 121° C (-65° to 250° F)

Temperature Effect

  • < ± 1.0 % of Full Scale/38° C (100° F)

Typical Applications

  • Clean Rooms
  • Energy/Water Management
  • Environmental Testing
  • Leak Detection
  • Medical Instruments